Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
Fernandes, Fabio; Simões, Marcus V.; Correia, Edileide de Barros; Marcondes-Braga, Fabiana G.; Coelho-Filho, Otavio Rizzi; Mesquita, Cláudio Tinoco; Mathias-Junior, Wilson; Antunes, Murillo; Arteaga-Fernández, Edmundo; Rochitte, Carlos Eduardo; Ramires, Felix José Alvarez; Alves, Silvia Marinho Martins; Montera, Marcelo Westerlund; Lopes, Renato Delascio; Oliveira-Junior, Mucio Tavares; Scolari, Fernando L.; Avila, Walkiria Samuel; Canesin, Manoel Fernandes; Bocchi, Edimar Alcides; Bacal, Fernando; Moura, Lídia Ana Zytynski; Saad, Eduardo Benchimol; Scanavacca, Mauricio I.; Valdigem, Bruno Pereira; Cano , Manuel Nicolas; Abizaid , Alexandre; Ribeiro, Henrique Barbosa; Lemos-Neto, Pedro Alves; Ribeiro, Gustavo Calado de Aguiar; Jatene, Fabio Biscegli; Dias, Ricardo Ribeiro; Beck-da-Silva, Luis; Rohde, Luis Eduardo P.; Bittencourt, Marcelo Imbroinise; Pereira, Alexandre; Krieger, José Eduardo; Villacorta, Humberto; Martins, Wolney de Andrade; Figueiredo-Neto, José Albuquerque de; Cardoso , Juliano Novaes; Pastore, Carlos Alberto; Jatene, Ieda Biscegli; Tanaka, Ana Cristina Sayuri; Hotta, Viviane Tiemi; Romano, Minna Moreira Dias; Albuquerque, Denilson Campos de; Mourilhe-Rocha, Ricardo; Hajjar, Ludhmila Abrahão; Brito, Fabio Sandoli de; Caramelli , Bruno; Calderaro, Daniela; Farsky, Pedro Silvio; Colafranceschi , Alexandre Siciliano; Pinto, Ibraim Masciarelli; Vieira , Marcelo Luiz Campos; Danzmann, Luiz Claudio; Barberato , Silvio Henrique; Mady, Charles; Martinelli-Filho, Martino; Torbey , Ana Flavia Malheiros; Schwartzmann, Pedro Vellosa; Macedo, Ariane Vieira Scarlatelli; Ferreira , Silvia Moreira Ayub; Schmidt, Andre; Melo , Marcelo Dantas Tavares de; Lima-Filho, Moysés Oliveira; Sposito, Andrei C.; Brito, Flavio de Souza; Biolo, Andreia; Madrini-Junior, Vagner; Rizk, Stéphanie Itala; Mesquita, Evandro Tinoco.
Preprint em Português | SciELO Preprints | ID: pps-8394

RESUMO

Hypertrophic cardiomyopathy (HCM) is a form of genetically caused heart muscle disease, characterized by the thickening of the ventricular walls. Diagnosis requires detection through imaging methods (Echocardiogram or Cardiac Magnetic Resonance) showing any segment of the left ventricular wall with a thickness > 15 mm, without any other probable cause. Genetic analysis allows the identification of mutations in genes encoding different structures of the sarcomere responsible for the development of HCM in about 60% of cases, enabling screening of family members and genetic counseling, as an important part of patient and family management. Several concepts about HCM have recently been reviewed, including its prevalence of 1 in 250 individuals, hence not a rare but rather underdiagnosed disease. The vast majority of patients are asymptomatic. In symptomatic cases, obstruction of the left ventricular outflow tract (LVOT) is the primary disorder responsible for symptoms, and its presence should be investigated in all cases. In those where resting echocardiogram or Valsalva maneuver does not detect significant intraventricular gradient (> 30 mmHg), they should undergo stress echocardiography to detect LVOT obstruction. Patients with limiting symptoms and severe LVOT obstruction, refractory to beta-blockers and verapamil, should receive septal reduction therapies or use new drugs inhibiting cardiac myosin. Finally, appropriately identified patients at increased risk of sudden death may receive prophylactic measure with implantable cardioverter-defibrillator (ICD) implantation.


La miocardiopatía hipertrófica (MCH) es una forma de enfermedad cardíaca de origen genético, caracterizada por el engrosamiento de las paredes ventriculares. El diagnóstico requiere la detección mediante métodos de imagen (Ecocardiograma o Resonancia Magnética Cardíaca) que muestren algún segmento de la pared ventricular izquierda con un grosor > 15 mm, sin otra causa probable. El análisis genético permite identificar mutaciones en genes que codifican diferentes estructuras del sarcómero responsables del desarrollo de la MCH en aproximadamente el 60% de los casos, lo que permite el tamizaje de familiares y el asesoramiento genético, como parte importante del manejo de pacientes y familiares. Varios conceptos sobre la MCH han sido revisados recientemente, incluida su prevalencia de 1 entre 250 individuos, por lo tanto, no es una enfermedad rara, sino subdiagnosticada. La gran mayoría de los pacientes son asintomáticos. En los casos sintomáticos, la obstrucción del tracto de salida ventricular izquierdo (TSVI) es el trastorno principal responsable de los síntomas, y su presencia debe investigarse en todos los casos. En aquellos en los que el ecocardiograma en reposo o la maniobra de Valsalva no detecta un gradiente intraventricular significativo (> 30 mmHg), deben someterse a ecocardiografía de esfuerzo para detectar la obstrucción del TSVI. Los pacientes con síntomas limitantes y obstrucción grave del TSVI, refractarios al uso de betabloqueantes y verapamilo, deben recibir terapias de reducción septal o usar nuevos medicamentos inhibidores de la miosina cardíaca. Finalmente, los pacientes adecuadamente identificados con un riesgo aumentado de muerte súbita pueden recibir medidas profilácticas con el implante de un cardioversor-desfibrilador implantable (CDI).


A cardiomiopatia hipertrófica (CMH) é uma forma de doença do músculo cardíaco de causa genética, caracterizada pela hipertrofia das paredes ventriculares. O diagnóstico requer detecção por métodos de imagem (Ecocardiograma ou Ressonância Magnética Cardíaca) de qualquer segmento da parede do ventrículo esquerdo com espessura > 15 mm, sem outra causa provável. A análise genética permite identificar mutações de genes codificantes de diferentes estruturas do sarcômero responsáveis pelo desenvolvimento da CMH em cerca de 60% dos casos, permitindo o rastreio de familiares e aconselhamento genético, como parte importante do manejo dos pacientes e familiares. Vários conceitos sobre a CMH foram recentemente revistos, incluindo sua prevalência de 1 em 250 indivíduos, não sendo, portanto, uma doença rara, mas subdiagnosticada. A vasta maioria dos pacientes é assintomática. Naqueles sintomáticos, a obstrução do trato de saída do ventrículo esquerdo (OTSVE) é o principal distúrbio responsável pelos sintomas, devendo-se investigar a sua presença em todos os casos. Naqueles em que o ecocardiograma em repouso ou com Manobra de Valsalva não detecta gradiente intraventricular significativo (> 30 mmHg), devem ser submetidos à ecocardiografia com esforço físico para detecção da OTSVE.   Pacientes com sintomas limitantes e grave OTSVE, refratários ao uso de betabloqueadores e verapamil, devem receber terapias de redução septal ou uso de novas drogas inibidoras da miosina cardíaca. Por fim, os pacientes adequadamente identificados com risco aumentado de morta súbita podem receber medida profilática com implante de cardiodesfibrilador implantável (CDI).

2.
Int J Cardiol ; 400: 131768, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38211668

RESUMO

BACKGROUND: Transcatheter edge-to-edge repair (TEER) has become an established treatment for primary and secondary mitral regurgitation (PMR and SMR). The objective of this study was to compare the accuracy of different risk scores for predicting 1-year mortality and the composite endpoint of 1-year mortality and/or heart failure (HF) hospitalization after TEER. METHODS: We analyzed data from 206 patients treated for MR at a tertiary European center between 2011 and 2023 and compared the accuracy of different mitral and surgical risk scores: EuroSCORE II, GRASP, MITRALITY, MitraScore, TAPSE/PASP-MitraScore, and STS for predicting 1-year mortality and the composite of 1-year mortality and/or HF hospitalization in PMR and SMR. A subanalysis of SMR-only patients with the addition of COAPT Risk Score and baseline N-Terminal pro-Brain Natriuretic Peptide (NT-proBNP) list was also performed. RESULTS: MITRALITY had the best discriminative ability for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with an area under the curve (AUC) of 0.74 and 0.74, respectively, in a composed group of PMR and SMR. In a SMR-only population, MITRALITY also presented the best AUC for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with values of 0.72 and 0.72, respectively. CONCLUSION: MITRALITY was the best mitral TEER risk model for both 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization in a population of PMR and SMR patients, as well as in SMR patients only. Surgical risk scores, MitraScore, TAPSE/PASP-MitraScore and NT-proBNP alone showed poor predictive values.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Hospitalização , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Fatores de Risco , Resultado do Tratamento
3.
Circulation ; 149(9): 644-655, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-37883682

RESUMO

BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Acidente Vascular Cerebral/etiologia
4.
Am J Cardiol ; 214: 8-17, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38104756

RESUMO

This study aimed to evaluate the incidence and clinical implications of myocardial injury, as determined by cardiac biomarker increase, in patients who underwent mitral bioprosthesis dysfunction treatment with transcatheter mitral valve replacement (TMVR) versus surgical mitral valve replacement reoperation (SMVR-REDO). Between 2014 and 2023, 310 patients with mitral bioprosthesis failure were included (90 and 220 patients for TMVR and SMVR-REDO, respectively). Multivariable analysis and propensity score matching were performed to adjust for the intergroup differences in baseline characteristics. Creatinine kinase-MB (CK-MB) and cardiac troponin I (cTn) were collected at baseline and 6 to 12, 24, 48, and 72 hours after intervention. The cardiac biomarkers values were evaluated in relation to their reference values. The outcomes were determined according to the Mitral Valve Academic Research Consortium criteria. CK-MB and cTn increased above the reference level in almost all patients after SMVR-REDO and TMVR (100% vs 94%, respectively), with the peak occurring within 6 to 12 hours. SMVR-REDO was associated with a two- to threefold higher increase in cardiac biomarkers. After 30 days, the mortality rates were 13.3% in the TMVR and 16.8% in the SMVR-REDO groups. At a median follow-up of 19 months, the mortality rates were 21.1% in the TMVR and 17.7% in the SMVR-REDO groups. Left ventricular ejection fraction, estimated glomerular filtration rate, CK-MB, and cTn were predictors of mortality. In conclusion, some degree of myocardial injury occurred systematically after the treatment of mitral bioprosthetic degeneration, especially after SMVR, and higher CK-MB and cTn levels were associated with increased cumulative late mortality, regardless of the approach.


Assuntos
Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Reoperação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Volume Sistólico , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Resultado do Tratamento , Função Ventricular Esquerda , Doenças das Valvas Cardíacas/cirurgia , Biomarcadores , Cateterismo Cardíaco/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos
5.
Arq Bras Cardiol ; 120(11): e20220496, 2023 Nov.
Artigo em Português, Inglês | MEDLINE | ID: mdl-38126512

RESUMO

BACKGROUND: Central Illustration : Percutaneous Strategies in Structural Heart Diseases: Focus on Chronic Heart Failure Transcatheter devices for monitoring and treating advanced chronic heart failure patients. PA: pulmonary artery; LA: left atrium; AFR: atrial flow regulator; TASS: Transcatheter Atrial Shunt System; VNS: vagus nerve stimulation; BAT: baroreceptor activation therapy; RDN: renal sympathetic denervation; F: approval by the American regulatory agency (FDA); E: approval by the European regulatory agency (CE Mark). BACKGROUND: Innovations in devices during the last decade contributed to enhanced diagnosis and treatment of patients with cardiac insufficiency. These tools progressively adapted to minimally invasive strategies with rapid, widespread use. The present article focuses on actual and future directions of device-related diagnosis and treatment of chronic heart failure.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Simpatectomia , Átrios do Coração , Rim
6.
Front Cardiovasc Med ; 10: 1228305, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028447

RESUMO

Background: Periprocedural myocardial injury (PPMI) frequently occurs after transcatheter aortic valve implantation (TAVI), although its impact on long-term mortality is uncertain. Methods: We performed a pooled analysis of Kaplan-Meier-derived individual patient data to compare survival in patients with and without PPMI after TAVI. Flexible parametric models with B-splines and landmark analyses were used to determine PPMI prognostic value. Subgroup analyses for VARC-2, troponin, and creatine kinase-MB (CK-MB)-defined PPMI were also performed. Results: Eighteen observational studies comprising 10,094 subjects were included. PPMI was associated with lower overall survival (OS) after two years (HR = 1.46, 95% CI 1.30-1.65, p < 0.01). This was also observed when restricting the analysis to overall VARC-2-defined PPMI (HR = 1.23, 95% CI 1.07-1.40, p < 0.01). For VARC-2 PPMI criteria and VARC-2 troponin-only, higher mortality was restricted to the first 2 months after TAVI (HR = 1.64, 95% CI 1.31-2.07, p < 0.01; and HR = 1.32, 95% CI 1.05-1.67, p = 0.02, respectively), while for VARC-2 defined CK-MB-only the increase in mortality was confined to the first 30 days (HR = 7.44, 95% CI 4.76-11.66, p < 0.01). Conclusion: PPMI following TAVI was associated with lower overall survival compared with patients without PPMI. PPMI prognostic impact is restricted to the initial months after the procedure. The analyses were consistent for VARC-2 criteria and for both biomarkers, yet CK-MB was a stronger prognostic marker of mortality than troponin.

7.
Am J Cardiol ; 205: 259-268, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37619492

RESUMO

Sacubitril-valsartan is an angiotensin receptor-neprilysin inhibitor (ARNI) associated with a decreased risk of death and hospitalization for selected patients with heart failure (HF). However, its association with improved atherosclerotic cardiovascular disease (ASCVD) events remains unclear. We performed a meta-analysis to evaluate the association of ARNI with ASCVD events in patients with HF. We systematically searched PubMed, Embase, Cochrane, and ClinicalTrials.gov for studies comparing ARNIs with angiotensin-converting enzyme inhibitors (ACEIs) or angiotensin receptor blockers (ARBs) in terms of myocardial infarction, stroke, angina pectoris, peripheral artery disease, and the composite end point in patients with HF. A total of 8 randomized controlled trials were included, with 17,541 patients assigned to either the ARNI (8,764 patients) or ACEi/ARB (8,777 patients) groups. The incidence of composite end point (risk ratio [RR] 1.03, 95% confidence interval [CI] 0.93 to 1.13, p = 0.63), myocardial infarction (RR 1.02, 95% CI 0.81 to 1.30, p = 0.85), angina pectoris (RR 0.96, 95% CI 0.80 to 1.17, p = 0.70), and stroke (RR 0.99, 95% CI 0.85 to 1.16, p = 0.93) were not statistically different between the ARNI and ACEi/ARB groups. However, ARNI was associated with a higher incidence of peripheral artery disease (RR 1.63, 95% CI 1.05 to 2.52, p = 0.03). In conclusion, this meta-analysis found no association between ARNI therapy and improved ASCVD events in patients with HF.


Assuntos
Aterosclerose , Doenças Cardiovasculares , Insuficiência Cardíaca , Infarto do Miocárdio , Doença Arterial Periférica , Acidente Vascular Cerebral , Humanos , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Antagonistas de Receptores de Angiotensina/uso terapêutico , Neprilisina , Doenças Cardiovasculares/epidemiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Aterosclerose/tratamento farmacológico , Aterosclerose/epidemiologia , Anti-Hipertensivos , Angina Pectoris , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/epidemiologia , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/epidemiologia , Antivirais
8.
Eur Heart J Acute Cardiovasc Care ; 12(11): 755-764, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37450613

RESUMO

AIMS: Chest pain is a major cause of medical evaluation at emergency department (ED) and demands observation to exclude the diagnosis of acute myocardial infarction (AMI). High-sensitivity cardiac troponin assays used as isolated measure and by 0- and 1-h algorithms are accepted as a rule-in/rule-out strategy, but there is a lack of validation in specific populations. METHODS AND RESULTS: The IN-HOspital Program to systematizE Chest Pain Protocol (IN-HOPE study) is a multicentre study that prospectively included patients admitted to the ED due to suspected symptoms of AMI at 16 sites in Brazil. Medical decisions of all patients followed the standard approach of 0 h/3 h protocol, but, in addition, blood samples were also collected at 0 and 1 h and sent to a central laboratory (core lab) to measure high-sensitivity cardiac troponin T (hs-cTnT). To assess the theoretical performance of 0 h/1 h algorithm, troponin < 12 ng/L with a delta < 3 was considered rule-out while a value ≥ 52 or a delta ≥ 5 was considered a rule-in criterion (the remaining were considered as observation group). The main objective of the study was to assess, in a population managed by the 0 h/3 h protocol, the accuracy of 0 h/1 h algorithm overall and in groups with a higher probability of AMI. All patients were followed up for 30 days, and potential events were adjudicated. In addition to the prospective cohort, a retrospective analysis was performed assessing all patients with hs-cTnT measured during the year of 2021 but not included in the prospective cohort, regardless of the indication of the test. A total of 5.497 patients were included (583 in the prospective and 4.914 in the retrospective analysis). The prospective cohort had a mean age of 57.3 (± 14.8) and 45.6% of females with a mean HEART score of 4.0 ± 2.2. By the core lab analysis, 74.4% would be eligible for a rule-out approach (45.3% of them with a HEART score > 3) while 7.3% would fit the rule-in criteria. In this rule-out group, the negative predictive value for index AMI was 100% (99.1-100) overall and regardless of clinical scores. At 30 days, no death or AMI occurred in the rule-out group of both 0/1 and 0/3 h algorithms while 52.4% of the patients in the rule-in group (0 h/1 h) were considered as AMI by adjudication. In the observation group (grey zone) of 0 h/1 h algorithm, GRACE discriminated the risk of these patients better than HEART score. In the retrospective analysis, 1.091 patients had a troponin value of <5 ng/L and there were no cardiovascular deaths at 30 days in this group. Among all 4.914 patients, the 30-day risk of AMI or cardiovascular death increased according to the level of troponin: 0% in the group < 5 ng/L, 0.6% between 5 and 14 ng/L, 2.2% between 14 and 42 ng/L, 6.3% between 42 and 90 ng/L, and 7.7% in the level ≥ 90 ng/L. CONCLUSION: In this large multicentre study, a 0 h/1 h algorithm had the potential to classify as rule-in or rule-out in almost 80% of the patients. The rule-out protocol had high negative predictive value regardless of clinical risk scores. Categories of levels of hs-cTn T also showed good accuracy in discriminating risk of the patients with a very favourable prognosis for cardiovascular death in the group with value < 5 ng/L. CLINICALTRIALS.GOV: NCT04756362.


Assuntos
Infarto do Miocárdio , Troponina T , Feminino , Humanos , Pessoa de Meia-Idade , Algoritmos , Biomarcadores , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Serviço Hospitalar de Emergência , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/epidemiologia , Estudos Prospectivos , Estudos Retrospectivos , Troponina I , Masculino , Adulto , Idoso
9.
EuroIntervention ; 19(7): 589-599, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37436190

RESUMO

BACKGROUND: The optimal timing to perform percutaneous coronary interventions (PCI) in transcatheter aortic valve implantation (TAVI) patients remains unknown. AIMS: We sought to compare different PCI timing strategies in TAVI patients. METHODS: The REVASC-TAVI registry is an international registry including patients undergoing TAVI with significant, stable coronary artery disease (CAD) at preprocedural workup. In this analysis, patients scheduled to undergo PCI before, after or concomitantly with TAVI were included. The main endpoints were all-cause death and a composite of all-cause death, stroke, myocardial infarction (MI) or rehospitalisation for congestive heart failure (CHF) at 2 years. Outcomes were adjusted using the inverse probability treatment weighting (IPTW) method. RESULTS: A total of 1,603 patients were included. PCI was performed before, after or concomitantly with TAVI in 65.6% (n=1,052), 9.8% (n=157) or 24.6% (n=394), respectively. At 2 years, all-cause death was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (6.8% vs 20.1% vs 20.6%; p<0.001). Likewise, the composite endpoint was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (17.4% vs 30.4% vs 30.0%; p=0.003). Results were confirmed at landmark analyses considering events from 0 to 30 days and from 31 to 720 days. CONCLUSIONS: In patients with severe aortic stenosis and stable coronary artery disease scheduled for TAVI, performance of PCI after TAVI seems to be associated with improved 2-year clinical outcomes compared with other revascularisation timing strategies. These results need to be confirmed in randomised clinical trials.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Intervenção Coronária Percutânea/métodos , Estenose da Valva Aórtica/terapia , Infarto do Miocárdio/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
10.
J. Transcatheter Interv ; 31(supl.1): 261-261, jul.-set. 2023. tab.
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1515753

RESUMO

INTRODUCTION: Inspiron® (Scitech, Brazil) is a 3rd generation drug eluting stent designed to create a fast and homogeneous endothelialization, possibly improving clinical outcomes. OBJECTIVES: The aim of this study was to evaluate the safety and efficacy of a sirolimus-eluting coronary stent, composed of a metallic chromium-cobalt platform with thin struts (75 µm), which releases sirolimus from a bioresorbable polymer applied only to the abluminal surface, in a real-world scenario, as a post-marketing clinical follow-up evaluation. METHODS: We pooled patient-level databases derived from the INSPIRION and LATITUDE prospective trials. Between June 2017 and January 2022, a total of 25 Brazilian centers included 2,803 patients that underwent percutaneous coronary intervention (PCI) in native coronary arteries lesions with Inspiron® (Scitech, Brazil) stent implantation. Exclusion criteria included target lesion located in saphenous vein or arterial graft, and use of coronary stent other than Inspiron® in the index procedure. The primary endpoint was a composite outcome of major adverse cardiovascular events (MACE) defined by the composite of cardiovascular death, myocardial infarction (MI) or target-lesion revascularization (TLR) at 12 months. The secondary outcomes included all-cause death, cardiovascular death, any MI, TLR, target-vessel revascularization (TVR), and probable and definite stent thrombosis at 12 months. RESULTS: The mean age was 62.0 ± 10.8 years, 36.5% had diabetes (12.7% on insulin), 17.6% had previous PCI and 54.9% presented with an acute coronary syndrome (ACS). At a median follow-up of 410 days, MACE occurred in 58 (2.1%) patients, all-cause death in 102 (3.6%), MI in 14 (0.5%), and target vessel revascularization in 2 (0.1%) patients. Definite or probable stent thrombosis occurred in 20 (0.7%) patients. CONCLUSIONS: The 1-year MACE rate, as well as the individual endpoint components, were low and consistent with previous results available for 3rd generation drug eluting stent. The result of this study demonstrates the safety and efficacy of this stent in a real-world population.

11.
European heart journal. Acute cardiovascular care ; 12(11): 755-764, jul.2023. ilus
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444830

RESUMO

BACKGROUND: Chest pain is a major cause of medical evaluation at emergency department (ED) and demands observation to exclude the diagnosis of acute myocardial infarction (AMI). High-sensitivity cardiac troponin assays used as isolated measure and by 0 h and 1 h algorithms are accepted as a rule-in/rule-out strategy but there is a lack of validation in specific populations. METHODS: The IN-HOspital Program to systematizE chest pain protocol (In Hope study) is a multicentre study that prospectively included patients admitted to the ED due to suspected symptoms of AMI at 16 sites in Brazil. Medical decisions of all patients followed the standard approach of 0/3-h protocol but, in addition, blood samples were also collected at 0 and 1 hour and sent to a central laboratory (core lab) to measure high-sensitivity troponin T (hs-cTnT). To assess the theoretical performance of 0/1-h algorithm, troponin < 12 ng/L with a delta <--- 3 was considered rule out while a value ≥ 52 and/or a delta ≥ 5 was considered a rule in criteria (the remaining were considered as observation group). The main objective of the study was to assess, in a population managed by the 0/3-h protocol, the accuracy of 0/1-h algorithm overall and in groups with higher probability of AMI. All patients were followed for 30 days, and potential events were adjudicated. In addition to the prospective cohort, a retrospective analysis was performed assessing all patients with hs-cTnT measured during the year of 2021 but not included in the prospective cohort, regardless the indication of the test. RESULTS: A total of 5.497 patients were included (583 in the prospective and 4.914 in the retrospective analysis). The prospective cohort had a mean age of 57.3 (± 14.8) and 45.6% of females with a mean HEART score of 4.0 ± 2.2. By the core lab analysis, 74.4% would be eligible for a rule-out approach (45.3% of HEART score > 3) while 7.3% would fit the rule-in criteria. In this rule-out group, the negative predictive value for index AMI was 100% (99.1-100) overall and regardless clinical scores. At 30 days, no death or AMI occurred in the rule-out group of both 0/1 and 0/3-hour while 52.4% of the patients in the rule-in group (0/1-hour) were considered as AMI by adjudication. In the observation group (grey zone) of 0/1- hour algorithm, GRACE discriminated the risk of these patients better than HEART score. In the retrospective analysis, 1.091 patients had a troponin value < 5 ng/L and there were no cardiovascular deaths at 30 days in this group. Among all 4.914 patients, the 30-day risk of AMI or cardiovascular death increased according to the level of troponin: 0% in the group < 5 ng/L, 0.6% between 5 and 14 ng/L, 2.2% between 14 and 42 ng/L, 6.3% between 42 and 90 ng/L and 7.7% in the level ≥ 90 ng/L. CONCLUSIONS: In this large multicentre study, a 0/1-h algorithm had the potential to classify as rule in or out almost 80% of the patients. The rule-out protocol had high negative predictive value regardless of clinical risk scores. Categories of levels of hs-cTn T also showed good accuracy in discriminating risk of the patients with a very favourable prognosis for cardiovascular death in the group with values < 5 ng/L.

12.
J. Transcatheter Interv ; 31(supl.1): 27-28, jul.-set. 2023.
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1512537

RESUMO

INTRODUCTION: In patients treated with bare metal stents and earlygeneration drug-eluting stents (DES) smaller stent diameter (SD) has been associated with worse long-term outcomes after percutaneous coronary intervention (PCI). Data on the impact of small SD on outcomes after PCI with third generation DES is scarce. OBJECTIVE: The aim of this study was to evaluate the impact of SD on clinical outcomes, using a third generation sirolimus-eluting coronary stent with thin struts and abluminal biodegradable polymer. METHODS: Consecutive patients treated with Inspiron® (Scitech, Brazil) in native coronary arteries lesions between June 2017 and January 2022 were included, in a total of 25 Brazilian centers. Patients were grouped according to SD: 3.50mm. One-year event rates were estimated using the Kaplan-Meier method and adjusted hazard ratios were generated using Cox regression analysis. The primary endpoint was a composite of major adverse cardiovascular events (MACE) defined by the composite of cardiovascular death, myocardial infarction (MI) or target-lesion revascularization (TLR) at 12 months. RESULTS: Of the 2,803 patients who underwent PCI with Inspiron®, 24,5% (n = 688) had SD ≤2.50 mm, 45.0% (n = 1,263) had SD 2.75-3.00mm and 30,4% (n = 852) had SD >3.50 mm. At 1 year, MACE rates were 3.1%, 2.1% and 1.3%, respectively, with increasing SD (p = 0.054). Death due to CV causes at 12 months rates decreased with increasing SD (2.9%, 1.8% and 0.8%, respectively [p < 0.009]) whereas rates of MI related study device at 12 months across SD groups were comparable (0.0%, 0.5%, and 0.1%, respectively [p = 0.086]). After multivariate stepwise Cox regression, smaller SD remained associated with higher rates of MACE (HR 0.46, 95%CI of 0.241-0.890; p=0.022). As seen in Figure 1, the risk of MACE is significantly increased in the first 30 days and remain higher up to 12 months among individuals with mean vessel diameter <2.50mm. CONCLUSIONS: In a large cohort of patients undergoing PCI with third generation DES MACE rates were low, but still higher among patients with smaller SD, mainly drive by higher CV deaths at 12 months. Further research into the optimal treatment strategy of small coronary arteries is still warranted.

13.
J. Transcatheter Interv ; 31(supl.1): 146-146, jul.-set. 2023.
Artigo em Português | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1513143

RESUMO

INTRODUÇÃO: Não existem estudos comparando os desfechos clínicos do implante de válvula aórtica transcateter (TAVI) com próteses balão-expansíveis (BE) versus auto-expansíveis (AE) de nova geração na realidade brasileira. OBJETIVO: Comparar os resultados clínicos intra-hospitalares de TAVI realizados com próteses BE de nova geração contra próteses AE de nova geração em centros brasileiros participantes do RIBAC-NT. MÉTODOS: Foram utilizados dados de centros ativamente participantes do registro brasileiro de TAVI. Critério de inclusão: todos os procedimentos de TAVI em válvula nativa tricúspide com utilização de próteses de nova geração. Critério de exclusão principal: procedimentos pela via transapical. Os casos foram separados conforme a prótese utilizada em grupo BE (Sapien S3, S3 Ultra e Myval) e AE (Evolut R, Evolut PRO, Acurate Neo, Acurate Neo2 e Portico). Desfecho primário analisado foi morte intra-hospitalar. Desfechos secundários: complicação vascular maior, sangramento maior, sangramento com risco de vida, qualquer acidente vascular encefálico (AVE) e novo implante de marcapasso. RESULTADOS: Ao todo 1703 pacientes de 25 centros foram incluídos na análise, sendo 887 no grupo BE e 819 no grupo AE. A idade média da população foi 80,7±7,2 anos e 48,9% eram mulheres. O grupo AE teve uma maior proporção de pacientes do sexo feminino (53,5% vs. 44,6%, P=<0,001), maior prevalência de doença arterial periférica (16,2% vs. 11%, P=0,002) e de doença pulmonar obstrutiva crônica (16,8% vs. 11,5%, P=0,002), além de Euroscore 2 maior (6,2 vs. 5,5, P=0,03). Tabela 1 estão demonstradas a comparação das características do procedimento entre os grupos. Pacientes do grupo BE realizaram mais procedimentos com anestesia geral, mais por via transfemoral e também com maior proporção de acessos totalmente percutâneos. No grupo AE houve maior necessidade de pré e pós-dilatação e discreta maior incidência de embolização e necessidade de uma segunda prótese, assim como maior incidência de oclusão coronariana. Tabela 2 sumariza o comparativo dos desfechos clínicos. Não houve diferença significativa para a mortalidade intra-hospitalar entre os grupos. Também não se observou diferença entre complicações vasculares, sangramentos, AVE e necessidade de novo marcapasso. Regressão logístico multivariada ajustando para diferenças entre os grupos não indicou diferença de mortalidade entre utilização de prótese BE vs. AE (OR 0,95, P=0,8). Preditores independentes de mortalidade foram sexo feminino (OR 0,49, P=0,009) e Euroscore 2 (OR 1,04, P=0,006). CONCLUSÃO: Em estudo de vida real de pacientes submetidos a TAVI no Brasil, não houve diferença da mortalidade intra-hospitalar entra a utilização de próteses BE de nova geração em comparação a utilização de próteses AE de nova geração.


Assuntos
Angioplastia com Balão , Substituição da Valva Aórtica Transcateter
14.
Front Cardiovasc Med ; 10: 1175600, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37388643

RESUMO

Background: Acute kidney injury (AKI) is frequently observed after transcatheter aortic valve implantation (TAVI). Of note, it is associated with a threefold increase in all-cause and cardiac death. We propose a new non-contrast strategy for evaluating and performing the TAVI procedure that can be especially valuable for patients with aortic stenosis (AS) and chronic kidney disease (CKD) to prevent AKI. Methods: Patients with severe symptomatic AS and CKD stage ≥3a were evaluated for TAVI using four non-contrast imaging modalities for procedural planning: transesophageal echocardiogram (TEE), cardiac magnetic resonance, multidetector computed tomography (MDCT), and aortoiliac CO2 angiography. Patients underwent transfemoral (TF) TAVI using the self-expandable Evolut R/Pro, and the procedures were guided by fluoroscopy and TEE. Contrast MDCT and contrast injection at certain checkpoints during the procedure were used in a blinded fashion to guarantee patient safety. Results: A total of 25 patients underwent TF-TAVI with the zero-contrast technique. The mean age was 79.9 ± 6.1 years, 72% in NYHA class III/IV, with a mean STS-PROM of 3.0% ± 1.5%, and creatinine clearance of 49 ± 7 ml/min. The self-expandable Evolut R and Pro were implanted in 80% and 20% of patients, respectively. In 36% of the cases, the transcatheter heart valve (THV) chosen was one size larger than the one by contrast MDCT, but none of these cases presented adverse events. Device success and the combined safety endpoint (at 30 days) both achieved 92%. Pacemaker implantation was needed in 17%. Conclusion: This pilot study demonstrated that the zero-contrast technique for procedural planning and THV implantation was feasible and safe and might become the preferable strategy for a significant population of CKD patients undergoing TAVR. Future studies with a larger number of patients are still needed to confirm such interesting findings.

15.
Front Cardiovasc Med ; 10: 1197408, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37378406

RESUMO

Introduction: Classical low-flow, low-gradient aortic stenosis (LFLG-AS) is an advanced stage of aortic stenosis, which has a poor prognosis with medical treatment and a high operative mortality after surgical aortic valve replacement (SAVR). There is currently a paucity of information regarding the current prognosis of classical LFLG-AS patients undergoing SAVR and the lack of a reliable risk assessment tool for this particular subset of AS patients. The present study aims to assess mortality predictors in a population of classical LFLG-AS patients undergoing SAVR. Methods: This is a prospective study including 41 consecutive classical LFLG-AS patients (aortic valve area ≤1.0 cm2, mean transaortic gradient <40 mmHg, left ventricular ejection fraction <50%). All patients underwent dobutamine stress echocardiography (DSE), 3D echocardiography, and T1 mapping cardiac magnetic resonance (CMR). Patients with pseudo-severe aortic stenosis were excluded. Patients were divided into groups according to the median value of the mean transaortic gradient (≤25 and >25 mmHg). All-cause, intraprocedural, 30-day, and 1-year mortality rates were evaluated. Results: All of the patients had degenerative aortic stenosis, with a median age of 66 (60-73) years; most of the patients were men (83%). The median EuroSCORE II was 2.19% (1.5%-4.78%), and the median STS was 2.19% (1.6%-3.99%). On DSE, 73.2% had flow reserve (FR), i.e., an increase in stroke volume ≥20% during DSE, with no significant differences between groups. On CMR, late gadolinium enhancement mass was lower in the group with mean transaortic gradient >25 mmHg [2.0 (0.0-8.9) g vs. 8.5 (2.3-15.0) g; p = 0.034), and myocardium extracellular volume (ECV) and indexed ECV were similar between groups. The 30-day and 1-year mortality rates were 14.6% and 43.8%, respectively. The median follow-up was 4.1 (0.3-5.1) years. By multivariate analysis adjusted for FR, only the mean transaortic gradient was an independent predictor of mortality (hazard ratio: 0.923, 95% confidence interval: 0.864-0.986, p = 0.019). A mean transaortic gradient ≤25 mmHg was associated with higher all-cause mortality rates (log-rank p = 0.038), while there was no difference in mortality regarding FR status (log-rank p = 0.114). Conclusions: In patients with classical LFLG-AS undergoing SAVR, the mean transaortic gradient was the only independent mortality predictor in patients with LFLG-AS, especially if ≤25 mmHg. The absence of left ventricular FR had no prognostic impact on long-term outcomes.

16.
Arq. bras. cardiol ; 120(11): e20220496, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1527782

RESUMO

Resumo As inovações em dispositivos ao longo das últimas décadas proporcionaram uma melhora no diagnóstico e tratamento de pacientes com insuficiência cardíaca. Essas novas ferramentas progressivamente adaptaram-se a estratégias minimamente invasivas e as opções percutâneas multiplicaram-se de forma rápida. No presente artigo revisamos as direções atuais e futuras dos dispositivos utilizados como opções adjuvantes para o diagnóstico e tratamento adjuvante na insuficiência cardíaca crônica, o seu desenvolvimento, mecanismos e estudos mais recentes


Abstract Innovations in devices during the last decade contributed to enhanced diagnosis and treatment of patients with cardiac insufficiency. These tools progressively adapted to minimally invasive strategies with rapid, widespread use. The present article focuses on actual and future directions of device-related diagnosis and treatment of chronic heart failure.

19.
J Cardiol Cases ; 26(3): 181-185, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36091613

RESUMO

Patients presenting with aortic stenosis and atrial fibrillation (AF) undergoing transcatheter aortic valve replacement (TAVR) are commonly at increased risk for stroke and bleeding complications. Concomitant left atrial appendage occlusion (LAAO) after TAVR may be an alternative to oral anticoagulation (OAC).Between 2018 and 2022, 7 consecutive patients who were ineligible for OAC underwent simultaneous TAVR and LAAO. The mean age was 84.9 ±â€¯4.9 years. The mean CHA2DS2-VASc, HAS-BLED, and STS predicted risk of mortality scores were 5.9 ±â€¯0.7, 3.9 ±â€¯1.1, and 8.8 ±â€¯3.4%, respectively. The median follow-up time was 23 (1 to 27) months. All procedures achieved technical success and no adverse events were observed during follow-up. This case series shows that concomitant TAVR and LAAO is feasible and safe among patients with severe aortic stenosis and AF who are deemed ineligible for OAC. Learning objectives: Atrial fibrillation is the most common arrhythmia in the transcatheter aortic valve replacement (TAVR) population. In those who experience major or life-threatening bleeding, mortality is doubled. We report a case series of 7 concomitant left atrial appendage occlusions (LAAO) after TAVR in patients ineligible for oral anticoagulation. All procedures achieved technical success and no adverse events were observed. The simultaneous approach with TAVR and LAAO was feasible and safe in this case series.

20.
Arq Bras Cardiol ; 118(6): 1085-1096, 2022.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35703645

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a worldwide adopted procedure with rapidly evolving practices. Regional and temporal variations are expected to be found. OBJECTIVE: To compare TAVR practice in Latin America with that around the world and to assess its changes in Latin America from 2015 to 2020. METHODS: A survey was applied to global TAVR centers between March and September 2015, and again to Latin-American centers between July 2019 and January 2020. The survey consisted of questions addressing: i) center's general information; ii) pre-TAVR evaluation; iii) procedural techniques; iv) post-TAVR management; v) follow-up. Answers from the 2015 survey of Latin-American centers (LATAM15) were compared with those of other centers around the world (WORLD15) and with the 2020 updated Latin-American survey (LATAM20). A 5% level of significance was adopted for statistical analysis. RESULTS: 250 centers participated in the 2015 survey (LATAM15=29; WORLD15=221) and 46 in the LATAM20. Combined centers experience accounted for 73 707 procedures, with WORLD15 centers performing, on average, 6- and 3-times more procedures than LATAM15 and LATAM20 centers, respectively. LATAM centers performed less minimalistic TAVR than WORLD15 centers, but there was a significant increase in less invasive procedures after 5 years in Latin-American centers. For postprocedural care, a lower period of telemetry and maintenance of temporary pacing wire, along with less utilization of dual antiplatelet therapy was observed in LATAM20 centers. CONCLUSION: Despite still having a much lower number of procedures, many aspects of TAVR practice in Latin-American centers have evolved in recent years, followingthe trend observed in developed country centers.


FUNDAMENTO: Implante transcateter de valva aórtica (TAVI) é um procedimento adotado em todo o mundo e suas práticas evoluem rapidamente. Variações regionais e temporais são esperadas. OBJETIVO: Comparar a prática de TAVI na América Latina com aquela no resto do mundo e avaliar suas mudanças na América Latina de 2015 a 2020. MÉTODO: A pesquisa foi realizada em centros de TAVI em todo o mundo entre março e setembro de 2015, e novamente nos centros latino-americanos entre julho de 2019 e janeiro de 2020. As seguintes questões foram abordadas: i) informação geral sobre os centros; ii) avaliação pré-TAVI; iii) técnicas do procedimento; iv) conduta pós-TAVI; v) seguimento. As respostas da pesquisa dos centros latino-americanos em 2015 (LATAM15) foram comparadas àquelas dos centros no resto do mundo (WORLD15) e ainda àquelas da pesquisa dos centros latino-americanos de 2020 (LATAM20). Adotou-se o nível de significância de 5% na análise estatística. RESULTADOS: 250 centros participaram da pesquisa em 2015 (LATAM15=29; WORLD15=221) e 46 na avaliação LATAM20. No total, foram 73.707 procedimentos, sendo que os centros WORLD15 realizaram, em média, 6 e 3 vezes mais procedimentos do que os centros LATAM15 e LATAM20, respectivamente. Os centros latino-americanos realizaram menor número de TAVI minimalista do que os do restante do mundo, mas aumentaram significativamente os procedimentos menos invasivos após 5 anos. Quanto à assistência pós-procedimento, observaram-se menor tempo de telemetria e de manutenção do marca-passo temporário, além de menor uso de terapia dupla antiplaquetária nos centros LATAM20. CONCLUSÃO: A despeito do volume de procedimentos ainda significativamente menor, muitos aspectos da prática de TAVI nos centros latino-americanos evoluíram recentemente, acompanhando a tendência dos centros dos países desenvolvidos.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , América Latina , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...